VITRO DATA CENTER PARANAQUE

VITRO DATA CENTER PARANAQUE

VITRO DATA CENTER PARANAQUE

Located on a one-hectare property in Parañaque City, the facility is a purpose-built telco-grade, carrier-neutral, international Internet Data Center.

Its privacy and security are ensured with a team of experts including IPC's 24x7 IDC staff, Network Operations Team, Customer Support, Security Team, and Automated Facility Monitoring System. This flagship Internet data center facility is accredited as part of the Nexcenter network of data centers, testament to its world-class quality.

Accredited by NTT Communications of Japan as one of its 140+ Nexcenter facilities around the world, VITRO Parañaque, owned and operated by IPC, is a purpose-built telco-grade, multi-carrier Internet Data Center.

VITRO DATA CENTER FEATURES

FACILITIES
  • 1,755 square meters / 800 racks

  • Network operations center

  • Staging area

  • Meet-me-rooms

  • Loading/ unloading dock

BUILDING STRUCTURE
  • Designed in accordance with the National Structure Code of the Philippines

  • Seismic Zone 4 Compliant

  • Designed to resist earthquake and wind load with respect to relevant international standards 

  • Structurally protected against seismic activity

  • Water leakage detection system

POWER
  • Independent power, 4mVA rating

  • 4 independent 1500kVA generator sets

  • 2N UPS in parallel configuration

  • Dual power feeds

COOLING BACKGROUND
  • Redundant chillers

  • Redundant precision air-conditioning units

  • Room temperature: 18 to 27 degrees Celsium per ASHRAE standards

  • Relative humidity: 40% to 60% per ASHRAE standards

OPERATIONS AND MAINTENANCE
  • 24 x 7 IDC staff

  • 24 x 7 Network Operations Team

  • 24 x 7 Customer Support

  • 24 x 7 Automated Facility Monitoring System

SECURITY
  • 24 x 7 stationary and roving security force

  • CCTV Monitoring System with CCTV cameras for every aisle and the entire facility

  • 7 stage Access Control and Mantrap System

  • Escorted access/Zoned environment control

PHYSICAL ENVIRONMENT
  • Anti-static raised flooring

  • Hot aisle / Cold aisle rack layout with perforated panels on Cold aisle

  • Overhead cable trays, separate for power and data cabling

  • IDC access requires foot covers to maintain cleanliness and sanitation

FIRE DETECTION AND SUPPRESSION
  • VESDA Aspiration System

  • Centralized Panel with Annunciator

  • FM 200 Fire Suppression System

NETWORK
  • Carrier Neutral- peered with local and international telco carriers